<LOGO>
FM Transmitter Measurement Report
Created: 2024-07-30 09-52-43
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 57 dBuV SANDELS
Pilot RDS Phase Difference
6.6 kHz 6.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 58 kHz 16271 4,8983
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,6 dBr 2,33 dBr 3,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 9 --:--
RT
-
AF EON
92.0, 94.7, 98.5, 106.3, 107.5 MHz -
FM Scope Max at: 58 kHz MIN: 13 kHz % above 76 kHz: 4,8983 Acquired: 2024/07/30 9.51.39 Total samples: 16271 Equivalent time: 0:13:33 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 3,9 dBr MIN: 0,6 dBr AVE: 2,33 dBr % above 12,2 dBr: 0,0 Last value: 3,1 dBr (2024/07/30 9.51.39) 09.38 09.40 09.42 09.44 09.46 09.48 09.50 -1 0 1 2 3 4 Pm [dBr]